Estancias del Rio: Current Settings


Sensata support of these products ends Dec 31, 2025.
Settings Date: 2025-12-22 06:08:54
Report received 7 seconds ago.
Inverter Settings
Model: MS4448PAE
Revision: 6.1
Stack Mode: Standalone Unit
Remote Settings
Revision: 4.0
AC Search: 5 watts
AC Shore Amps: 30
Low VAC Dropout: UPS Mode
Charge Rate: 0% of full value
Auto Generator Start: Off
Battery Size:400 amp/hours
Low Battery Cut-Out: 48.8 VDC
Absorb Voltage: 56.8 VDC
Float Voltage: 56.8 VDC
Equalize Voltage: 56.8 VDC
Battery Monitor
Revision: 1.0
Battery Efficiency: 99%
Battery Size:400 amp/hours
MagWeb
Firmware Date: 2011-06-13


Sensata support of these products ends Dec 31, 2025.