Settings Date: |
2025-07-16 15:28:03 Report received 6 seconds ago. |
---|---|
Inverter Settings | |
Model: | MS4024PAE |
Revision: | 6.1 |
Stack Mode: | Standalone Unit |
Remote Settings | |
Revision: | 4.0 |
AC Search: | No Searching, Always On |
AC Shore Amps: | 30 |
Low VAC Dropout: | 60 VAC |
Charge Rate: | 80% of full value |
Auto Generator Start: | Enabled |
Battery Size: | 460 amp/hours |
Low Battery Cut-Out: | 23.6 VDC |
Absorb Voltage: | 28.8 VDC |
Float Voltage: | 26.4 VDC |
Equalize Voltage: | 28.8 VDC |
Automatic Generator Start Settings (controlled by ME-ARC) |
|
AGS Revision: | 6.1 |
Start Generator When: | |
Battery Voltage: | @ 24.4 volts for [1m 0s], run to 28.8 volts for [1m 0s] |
Generator Settings: | |
Warm Up Time: | [2m 0s] |
Cool Down Time: | [2m 0s] |
Max Run Time: | [6h 0m] |
Generator Exercise: | Every 30 days at 08:00 for [12m]. |
Battery Monitor | |
Revision: | 1.3 |
Battery Efficiency: | 99% |
Battery Size: | 460 amp/hours |
MagWeb | |
Firmware Date: | 2011-06-13 |