Data Date: |
2024-03-28 14:48:53 CDT
Report received ago. |
---|---|
Battery Monitor (ME-BMK) | |
State of Charge: |
99%
|
volts / amps: |
14.29 VDC @ 69.8 amps (997 watts)
|
Amp Hours In / Out: |
-1 amp hours |
volts Min / volts Max: | 10.49 VDC Min / 15.72 VDC Max |
rAH / tAH Out: | 6,553.5 AH / 9.8 kAH |
Inverter (MSH3012M) | |
Status: | Absorb Mode Absorbing with AC. |
LEDs: |
Inverting Charging |
Battery Temperature: | 22°C / 71°F |
Transformer Temperature: | 37°C / 98°F |
FET Temperature: | 39°C / 102°F |
AC Out: | Approximately 118 volts AC @ 0 amps |
AC In: | Approximately 10 amps |
AC Frequency: | 60.0 |
DC volts / amps: (Values are approximate) |
14.5 VDC @ 77 amps (1116 watts) |
AGS / Generator | |
Status: | AC In |
AGS Temperature: | 22°C / 73°F |
AGS Voltage: | 14.50 VDC |
Generator Runtime: | [12m 0s] |
Days Since Last Run: | 6 days |
Battery Monitor | |||
---|---|---|---|
Minimum | Maximum | Average | |
State of Charge: (% full) | 99 | 100 | 99.3 |
DC volts: | 13.24 | 14.83 | 13.72 |
DC amps: | -7.0 | 89.8 | 0.1 |
Inverter | |||
Minimum | Maximum | Average | |
AC volts Out: (when volts > 80) |
116 | 123 | 120.6 |
AC amps Out: (when not charging) |
0 | 0 | 0.0 |
AC amps Out: (when charging) |
-1 | 1 | 0.2 |
AC amps In: | 0 | 18 | 0.7 |
AC Frequency: (Hz) | 59.6 | 60.3 | 60.0 |
Battery Temperature: | 15°C / 59°F | 22°C / 71°F | 18°C / 65°F |
Transformer Temperature: | 31°C / 87°F | 38°C / 100°F | 35°C / 95°F |
FET Temperature: | 26°C / 78°F | 39°C / 102°F | 29°C / 85°F |
AGS | |||
Minimum | Maximum | Average | |
AGS Temperature: | 14°C / 58°F | 22°C / 73°F | 18°C / 64°F |
AGS Voltage: (volts DC) | 13.30 | 14.80 | 13.73 |