username:
password:
Sign In
How To Register

GL Earthship : Current Conditions


Note: If you are having an issue with viewing the page, hold down the shift key on your keyboard and press the refresh button on your browser

Now

Data Date: 2018-11-12 21:47:02 UTC
Report received ago.
Battery Monitor (ME-BMK)
State of Charge: 98%
volts / amps: 25.26 VDC @ -2.0 amps (-50 watts)
Amp Hours In / Out: -13 amp hours
volts Min / volts Max: 24.09 VDC Min / 31.18 VDC Max
rAH / tAH Out:5,836.0 AH / 5.8 kAH
Inverter (MS4024PAE)
Status: Inverting
LEDs: LED for Inverter Inverting
LED for Battery Charging Charging
Battery Temperature:17°C / 62°F
Transformer Temperature:34°C / 93°F
FET Temperature:28°C / 82°F
AC Out:Approximately 121 volts AC @ 0 amps
AC In:Inactive.
AC Frequency:60.0
DC volts / amps:
(Values are approximate)
25.2 VDC @ 0 amps (0 watts)

Last 24 Hours

Battery Monitor
Minimum Maximum Average
State of Charge: (% full) 96 100 98.3
DC volts: 25.24 29.61 25.92
DC amps: -2.2 23.8 0.2
Inverter
Minimum Maximum Average
AC volts Out:
(when volts > 80)
114 124 120.0
AC amps Out:
(when not charging)
0 0 0.0
AC amps Out:
(when charging)
0 0 0.0
AC amps In: 0 0 0.0
AC Frequency: (Hz) 60.0 60.0 60.0
Battery Temperature: 17°C / 62°F 17°C / 62°F 17°C / 62°F
Transformer Temperature: 34°C / 93°F 36°C / 96°F 34°C / 93°F
FET Temperature: 28°C / 82°F 29°C / 84°F 28°C / 82°F
Data from approximately Loading... ago